Our specialists will reach out shortly.

Water Testing Equipment

Fison Water Testing Equipment with temperature sensors measures water temperature, which affects chemical reactions and aquatic health. Their built-in calibration feature requires minimal maintenance, ensuring long-term reliability. They come with long-lasting batteries, reducing the frequency of recharging or battery changes during fieldwork. These support continuous real-time monitoring of water quality, providing ongoing data for critical applications. Our Water Testing Equipment provides high-performance sensors with accurate and dependable water quality measurements.

Benchtop Conductivity Meter FM-BCT-A100

  • Conductivity Range : 0.000 μS/cm to 3000 mS/cm
  • Conductivity Resolution : 0.001 μS/cm minimum, varies with range selection
  • Conductivity Accuracy : ±0.5% FS
  • Conductivity Reference Temperature : 5, 10, 15, 18, 20, 25 °C
Catalog

Benchtop Water Hardness Meter FM-BWM-A100

  • Measurement range : 0.05 to 200 mmol/L, 0 to 1404⁰, 0 to 8020 mg/L (Ca2+), 0 to 19999 mg/L (CaCO3)
  • Measurement resolution : 0.001, 0.01, 0.1, 1
  • Measurement accuracy : ± 1% F.S.
  • Calibration points : 2 to 5 points (0.01, 0.1, 1, 10, 100 mmol/L)
Catalog

Chlorine Analyzer FM-CHA-A100

  • Free Chlorine Range : 0-20.00 mg/L(ppm)
  • Free Chlorine Accuracy : ±1% or ±0.01 mg/L
  • Hypochlorous Acid (HOCl) Range : 0 to 10.00 mg/L(ppm)
  • Hypochlorous Acid (HOCl) Accuracy : ±1% or ±0.01 mg/L
Catalog
COD Thermoreactor FM-COD-A100
  • Digestion Capacity : 0 to 12mL
  • Digestion Pipe Diameter : Φ16mm
  • Digestion Temperature : 30 to 190℃
  • Heating Rate : Upto 165 ℃ within 10 minutes
Catalog
COD Reactor FM-COD-B102
  • Temperature Control Range : Rt ~180°C
  • Digestion Temperature : 50~180°C
  • Temperature Control Accuracy : ±0.1°C
  • Temperature Tolerance : ±1°C
Catalog

COD Reactor FM-COD-B101

  • Temperature Range : 45-180℃
  • Accuracy : ±0.1°C (@ 25°C)
  • Environmental Temperature : 0-60℃
  • Capacity : 16 vials
Catalog

Conductivity Analyzer FM-CAN-A100

  • Measuring Range (EC) : 2.0 to 2000µS/cm (with K = 1.0 electrode)
  • Measuring Range (TDS) : 1.0 to 1000 ppm
  • Accuracy : ±2% FS
  • Temperature range : -10 to +130 0C
Catalog

Cyanide Analyzer FM-CA-A100

  • Measuring range : 0 to 1mg/L(segmented)
  • LOD : 0.004mg/L
  • Minimum display value : 0.001mg
  • Working Temperature : 15 to 40℃
Catalog
Dissolved Oxygen Meter FM-DOM-A100
  • Range : 0.00 to 20.00mg/L
    0.0 to 200.0% saturation
  • Resolution : 0.01mg/L, 0.1%
  • Accuracy : ±0.2mg/L, ±2.0%
  • Calibration Points : 1 or 2 points
Catalog
Smart Water Activity Meter FM-SWA-A100
  • Water Activity Measuring Range : 0 to 1 aw
  • Water Activity Accuracy : ± 0.012 aw, 23℃ ± 5℃
  • Water Activity Resolution : 0.001 aw
  • Water Activity Repeatability : ≤ 0.008 aw
Catalog

TDS Monitor FM-TDS-A100

  • Electrical Conductivity Range : 0 to 9999μS/ 0 to 9.99mS
  • Total Dissolved Solids Range : 0 to 5000ppm/ 0 to 5ppt
  • Resolution EC : 0.1μS (0 to 99.9), 1μS (100 to 999), 10μS (1000 to 9990), 0.01mS (0.00 to 9.99)
  • Resolution TDS : 0.1ppm (0 to 99.9), 1ppm (100 to 999), 10ppm (1000 to 5000), 0.01 ppt (0.00 to 5.00)
Catalog