Our specialists will reach out shortly.

Spectrophotometer

Fison Spectrophotometers offer high-precision optical system, ensuring accurate measurement of light absorbance and transmittance. They feature multiple measurement modes, supporting absorbance, transmittance, and concentration measurements for versatile testing. These units provide rapid analysis, delivering quick results with minimal sample preparation. They provide USB and printer connectivity for easy data transfer and reporting. Our Spectrophotometers are built with a durable and compact design, ensuring longevity and reliability.

Atomic Absorption Spectrophotometer FM-AAS-A100

  • Wavelength range  : 190 to 900 nm
  • Wavelength accuracy : ≤ ±0.5 nm
  • Wavelength repeatability : ≤0.3 nm (single direction)
  • Spectrum bandwidth : 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A101

  • Wavelength range  : 190 to 900 nm
  • Wavelength accuracy : ± 0.15 nm
  • Wavelength repeatability : ≤ 0.04 nm
  • Spectrum bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A200

  • Main specification :
    Wavelength range190 to 900 nm
    Wavelength accuracy±0.5 nm
    ResolutionTwo spectral lines of Mn at 279.5 nm and 279.8 nm, can be separated with spectral bandwidth of 0.2 nm and valley-peak energy ratio less than 30%
    Baseline stability0.005 A/30 min
    Background correctionD2 lamp background correction capability at 1A is better than 30 times
  • Light source system :
    Lamp turret2 lamps powered simultaneously (one preheated)
    Lamp current adjustment0 to 20 mA
    Lamp power supply mode400 Hz square wave pulse
  • Optical system :
    MonochromatorSingle beam, Czerny-Turner design grating monochromator
    Grating1800 lines/mm
    Focal length277 mm
    Blazed wavelength250 nm
    Spectral bandwidth0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm, automatic change
    Spectral adjustmentManual adjustment for wavelength and slit
  • Flame Atomizer :
    Burner10 cm single slot all-titanium burner
    Spray chamberCorrosion resistant all-plastic spray chamber
    NebulizerHigh efficiency glass nebulizer with metal sleeve, sucking up rate:6-7 ml/min
    Position adjustmentManual adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner/min
    Gas line protectionFuel gas leakage alarm/min
Catalog
Atomic Absorption Spectrophotometer FM-AAS-A201
  • Main specification :
    Wavelength range190 to 900 nm
    Wavelength accuracy± 0.25 nm
    ResolutionTwo spectral lines of Mn at 279.5 nm and 279.8 nm can be separated with the spectral bandwidth of 0.2 nm and valley peak energy ratio less than 30%
    Baseline stability≤0.004 A/30 min
    Background correctionD2 lamp background correction capability at 1A is better than 30 times
  • Light source system :
    Lamp turret4-lamp turret auto alignment, fully automated scan and peak-picking
    Lamp current adjustmentAutomatic adjustment and display
    Wide pulse current: 0 to 25 mA,
    Narrow pulse current: 0 to 10 mA                
    Lamp power supply mode400 Hz square wave pulse
  • Optical system :
    MonochromatorSingle beam, Czerny-Turner design grating monochromator
    Grating1800 lines/mm
    Focal length277 mm
    Blazed wavelength250 nm
    Spectral bandwidth0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm automatic change
  • Flame Atomizer :
    Burner10 cm single slot all-titanium burner  
    Spray chamberCorrosion resistant all-plastic spray chamber
    NebulizerHigh efficiency glass nebulizer with metal sleeve, sucking up rate: 6 to 7 mL/min
Catalog
Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D100
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam; Grating 1200 lines/mm
  • Wavelength accuracy : ±0.5 nm
Catalog

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D101

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Optical system : Double beam; Grating 1600 lines/mm
  • Wavelength accuracy : ±0.3 nm
Catalog

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D102

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.5/1/2/4/5 nm; Auto adjustable
  • Optical system : Double beam; Grating 1600 lines/mm
  • Wavelength accuracy : ±0.3 nm
Catalog

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D200

  • Wavelength range : 190 to 900 nm
  • Spectral bandwidth : Continuous slit 0.1 to 5.0 nm with 0.1 nm interval
  • Optical system : Double beam
  • Wavelength accuracy : ±0.3 nm
Catalog
Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D201
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Wavelength accuracy : ± 0.3 nm
  • Wavelength repeatability : ≤ 0.2 nm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C100
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C101

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.0 nm
  • Optical system : Double beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C102

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 0.5, 1, 2 and 4 nm
  • Optical system : Double beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C200

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Split beam; 1200 lines/mm grating
  • Wavelength accuracy : ±0.3 nm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C201
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Optical system : Split beam; 1200 lines/mm grating
  • Wavelength accuracy : ±0.3 nm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C202
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.5 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
Catalog

Fluorescence Spectrophotometer FM-FS-A100

  • Light source : LED
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10nm
  • Optical filter beam size : 25 mm
Catalog

Fluorescence Spectrophotometer FM-FS-A101

  • Light source : Xenon lamp 150 W
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10 nm
  • Optical filter beam size : 25 mm
Catalog

Fluorescence Spectrophotometer FM-FS-A200

  • Light source : 150 W xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
  • Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
Catalog
Fluorescence Spectrophotometer FM-FS-A201
  • Light source : 150 W xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
  • Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
Catalog
Fluorescence Spectrophotometer FM-FS-A202
  • Wavelength Range : 200nm to 900nm
  • Detection Sensitivity : S/N ≥ 150 (P-P)
  • Excitation Wavelength Bandwidth : 10nm
  • Microprocessor : PID 0 to 199.9
Catalog

Handheld Spectrophotometer FM-HSP-A100

  • Optical Geometry : Reflect: di:8°, de:8° (diffused illumination, 8-degree viewing angle)
  • Integrating Sphere Size : Φ40 mm
  • Light Source : Combined full spectrum LED light source, UV light source
  • Spectrophotometric Mode : Flat Grating
Catalog

Micro Spectrophotometer FM-MS-A100

  • Wavelength : 180 to 910 nm; Cuvette: 600±8 nm
  • Wavelength Accuracy : ±1 nm
  • Sample Volume : 0.5 to 2.0 μl
  • Absorbance Range (equaled 10mm) : 0.02 to 300A; Cuvette (OD600): 0 to 4A
Catalog

Nano Spectrophotometer FM-NS-A100

  • Absorbance precision : 0.002 Abs
  • Wavelength detector : 2048 element linear CMOS array
  • Sample volume : 0.5μl to 2μl (recommended 2μl)
  • Absorbance accuracy : ±1% (7.332 at 260nm)
Catalog
NIR Spectrophotometer FM-NIS-A100
  • Optical System : Grating Monochromator
  • Measurement Mode : Transmission
  • Wavelength Range : 900 nm to 2500 nm
  • Wavelength Accuracy : ≤ 0.2
Catalog
NIR Spectrophotometer FM-NIS-A101
  • Measurement Mode : Diffuse reflection sample pool
  • Wavelength Range : 900 nm to 2500 nm
  • Wavelength Accuracy : ≤ 0.2 nm
  • Wavelength Reproducibility : ≤ 0.05 nm
Catalog

Portable NIR Spectrophotometer FM-PNS-A100

  • Wavelength range : 1000 to 1800 nm
  • Wavelength accuracy : ≤ + 0.2 nm
  • Light Source : Tungsten halogen lamp
  • Detector : High performance ultra-cooled lnGaAs (Indium Gallium Arsenide)
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B100

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B101

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B102
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B103
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 0.5, 1, 2 and 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B104

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A101

  • Wavelength range : 200 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 2 nm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A102

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog
Single Beam UV-Visible Spectrophotometer FM-UVS-A103
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog
Single Beam UV-Visible Spectrophotometer FM-UVS-A200
  • Wavelength range : 200 to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam
  • Wavelength accuracy : ± 2 nm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A201

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam
  • Wavelength accuracy : ± 0.5 nm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A300

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 0.5/1/2/4/5 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
Catalog

Visible Spectrophotometer FM-VS-A100

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 2 nm
Catalog
Visible Spectrophotometer FM-VS-A101
  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 2 nm
Catalog
Visible Spectrophotometer FM-VS-A102
  • Wavelength range : 320 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog

Visible Spectrophotometer FM-VS-A103

  • Wavelength range : 320 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog

Visible Spectrophotometer FM-VS-B100

  • Wavelength Range : 320 to 1100 nm
  • Bandwidth : 4 nm
  • Wavelength Accuracy : ±0.5 nm
  • Wavelength Repeatability : ≤0.2 nm
Catalog

Visible Spectrophotometer FM-VS-C100

  • Wavelength Range : 360 to 780 nm
  • Wavelength Interval : 10nm
  • Half Bandwidth : 5nm
  • Transmittance Range : 0 to 200%
Catalog