Our specialists will reach out shortly.

Spectrophotometer

Fison Spectrophotometers offer high-precision optical system, ensuring accurate measurement of light absorbance and transmittance. They feature multiple measurement modes, supporting absorbance, transmittance, and concentration measurements for versatile testing. These units provide rapid analysis, delivering quick results with minimal sample preparation. They provide USB and printer connectivity for easy data transfer and reporting. Our Spectrophotometers are built with a durable and compact design, ensuring longevity and reliability.

Atomic Absorption Spectrophotometer FM-AAS-A100

  • Wavelength range  : 190 to 900 nm
  • Wavelength accuracy : ≤ ±0.5 nm
  • Wavelength repeatability : ≤0.3 nm (single direction)
  • Spectrum bandwidth : 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A101

  • Wavelength range  : 190 to 900 nm
  • Wavelength accuracy : ± 0.15 nm
  • Wavelength repeatability : ≤ 0.04 nm
  • Spectrum bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A200

  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : ±0.5 nm
  • Resolution : Two spectral lines of Mn at 279.5 nm and 279.8 nm, separable with spectral bandwidth of 0.2 nm and valley-peak energy ratio < 30%
  • Baseline Stability : 0.005 A/30 min
Catalog
Atomic Absorption Spectrophotometer FM-AAS-A201
  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : ± 0.25 nm
  • Resolution : Two spectral lines of Mn at 279.5 nm and 279.8 nm, separable with a spectral bandwidth of 0.2 nm and valley-peak energy ratio < 30%
  • Baseline Stability : ≤0.004 A/30 min
Catalog
Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D100
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam; Grating 1200 lines/mm
  • Wavelength accuracy : ±0.5 nm
Catalog

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D101

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Optical system : Double beam; Grating 1600 lines/mm
  • Wavelength accuracy : ±0.3 nm
Catalog

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D102

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.5/1/2/4/5 nm; Auto adjustable
  • Optical system : Double beam; Grating 1600 lines/mm
  • Wavelength accuracy : ±0.3 nm
Catalog

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D200

  • Wavelength range : 190 to 900 nm
  • Spectral bandwidth : Continuous slit 0.1 to 5.0 nm with 0.1 nm interval
  • Optical system : Double beam
  • Wavelength accuracy : ±0.3 nm
Catalog
Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D201
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Wavelength accuracy : ± 0.3 nm
  • Wavelength repeatability : ≤ 0.2 nm
Catalog
Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D300
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength accuracy : ±0.3 nm
  • Wavelength reproducibility : ≤0.15 nm
Catalog

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D202

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 0.1, 0.2, 0.5, 1, 2, 5 nm variable
  • Wavelength accuracy : ±0.3 nm
  • Wavelength reproducibility : 0.1 nm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C100

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C101

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.0 nm
  • Optical system : Double beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C102
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 0.5, 1, 2 and 4 nm
  • Optical system : Double beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C200
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Split beam; 1200 lines/mm grating
  • Wavelength accuracy : ±0.3 nm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C201

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 1 nm
  • Optical system : Split beam; 1200 lines/mm grating
  • Wavelength accuracy : ±0.3 nm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C202

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.5 nm
  • Wavelength Accuracy : ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.2 nm
Catalog

Fluorescence Spectrophotometer FM-FS-A100

  • Light source : LED
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10nm
  • Optical filter beam size : 25 mm
Catalog
Fluorescence Spectrophotometer FM-FS-A101
  • Light source : Xenon lamp 150 W
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10 nm
  • Optical filter beam size : 25 mm
Catalog
Fluorescence Spectrophotometer FM-FS-A200
  • Light source : 150 W xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
  • Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
Catalog

Fluorescence Spectrophotometer FM-FS-A201

  • Light source : 150 W xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
  • Excitation slit : 2 nm, 5 nm, 10 nm, 20 nm
Catalog

Fluorescence Spectrophotometer FM-FS-A202

  • Wavelength Range : 200nm to 900nm
  • Detection Sensitivity : S/N ≥ 150 (P-P)
  • Excitation Wavelength Bandwidth : 10nm
  • Microprocessor : PID 0 to 199.9
Catalog

Handheld Spectrophotometer FM-HSP-A100

  • Optical Geometry : Reflect: di:8°, de:8° (diffused illumination, 8-degree viewing angle)
  • Integrating Sphere Size : Φ40 mm
  • Light Source : Combined full spectrum LED light source, UV light source
  • Spectrophotometric Mode : Flat Grating
Catalog
Micro Spectrophotometer FM-MS-A100
  • Wavelength : 180 to 910 nm; Cuvette: 600±8 nm
  • Wavelength Accuracy : ±1 nm
  • Sample Volume : 0.5 to 2.0 μl
  • Absorbance Range (equaled 10mm) : 0.02 to 300A; Cuvette (OD600): 0 to 4A
Catalog
Nano Spectrophotometer FM-NS-A100
  • Absorbance precision : 0.002 Abs
  • Wavelength detector : 2048 element linear CMOS array
  • Sample volume : 0.5μl to 2μl (recommended 2μl)
  • Absorbance accuracy : ±1% (7.332 at 260nm)
Catalog

NIR Spectrophotometer FM-NIS-A100

  • Optical System : Grating Monochromator
  • Measurement Mode : Transmission
  • Wavelength Range : 900 nm to 2500 nm
  • Wavelength Accuracy : ≤ 0.2
Catalog

NIR Spectrophotometer FM-NIS-A101

  • Measurement Mode : Diffuse reflection sample pool
  • Wavelength Range : 900 nm to 2500 nm
  • Wavelength Accuracy : ≤ 0.2 nm
  • Wavelength Reproducibility : ≤ 0.05 nm
Catalog

Portable NIR Spectrophotometer FM-PNS-A100

  • Wavelength range : 1000 to 1800 nm
  • Wavelength accuracy : ≤ + 0.2 nm
  • Light Source : Tungsten halogen lamp
  • Detector : High performance ultra-cooled lnGaAs (Indium Gallium Arsenide)
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B100
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B101
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B102

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B103

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 0.5, 1, 2 and 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B104

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.3 nm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B200
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength accuracy : ±0.5 nm
  • Wavelength reproducibility : ≤0.2 nm
Catalog
Single Beam UV-Visible Spectrophotometer FM-UVS-A101
  • Wavelength range : 200 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 2 nm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A102

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A103

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A200

  • Wavelength range : 200 to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam
  • Wavelength accuracy : ± 2 nm
Catalog
Single Beam UV-Visible Spectrophotometer FM-UVS-A201
  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam
  • Wavelength accuracy : ± 0.5 nm
Catalog
Single Beam UV-Visible Spectrophotometer FM-UVS-A300
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 0.5/1/2/4/5 nm
  • Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
  • Wavelength Repeatability : ≤ 0.1 nm
Catalog

Split Beam Scanning UV-Visible Spectrophotometer FM-SUV-A100

  • Wavelength range : 190 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength accuracy : ±0.3 nm
  • Wavelength reproducibility : 0.15 nm
Catalog

Visible Spectrophotometer FM-VS-A100

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 2 nm
Catalog

Visible Spectrophotometer FM-VS-A101

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 2 nm
Catalog
Visible Spectrophotometer FM-VS-A102
  • Wavelength range : 320 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog
Visible Spectrophotometer FM-VS-A103
  • Wavelength range : 320 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
  • Wavelength accuracy : ± 0.5 nm
Catalog

Visible Spectrophotometer FM-VS-B100

  • Wavelength Range : 320 to 1100 nm
  • Bandwidth : 4 nm
  • Wavelength Accuracy : ±0.5 nm
  • Wavelength Repeatability : ≤0.2 nm
Catalog

Visible Spectrophotometer FM-VS-C100

  • Wavelength Range : 360 to 780 nm
  • Wavelength Interval : 10nm
  • Half Bandwidth : 5nm
  • Transmittance Range : 0 to 200%
Catalog

Visible Spectrophotometer FM-VS-D100

  • Wavelength range : 320 to 1100 nm
  • Spectral bandwidth : 2 nm
  • Wavelength accuracy : ±0.5 nm
  • Wavelength reproducibility : ≤0.2 nm
Catalog