Single Beam UV-Visible Spectrophotometer FM-UVS-A101

Single Beam UV-Visible Spectrophotometer FM-UVS-A101

Single Beam UV-Visible Spectrophotometer FM-UVS-A101 operates with wavelength range of 200 nm to 1000 nm and spectral bandwidth 4 nm. Equipped with large LCD display and a USB interface which allows it to plug directly to computer for output results. It uses silicon photodiode detector, deuterium and tungsten lamp as light source which provides best wavelength coverage across working range of spectrophotometer. This single beam spectrophotometer has highly stable optics with 1200 lines/mm grating. System save test results up to 200 group data and 100 standard curves.

Specifications

Wavelength range 200 nm to 1000 nm
Spectral bandwidth 4 nm
Optical system Single beam, grating 1200 lines / mm
Wavelength accuracy ± 2 nm
Wavelength repeatability 1 nm
Photometric range T: 0 to 200% , A: (-0.3) to 3, C: 0 to 9999
Photometric accuracy T: ≤ ±0.5%, A: ±0.003 % @ 1 A
Light source Tungsten lamp and deuterium lamp
Stray light 0.3 % T
Stability ±0.002 A/h @ 500 nm
Display LCD (128 × 64 dots)
Standard cell holder 4 position 10 mm cell changer
Sample compartment Standard 10 mm path length cuvette
Detector Silicon photodiode
Output USB port and parallel port (printer)
Power requirement AC 110 / 220 V, 50 / 60 Hz
Dimensions (W × D × H) 470 × 370 × 180 mm
Weight 14 kg

Features

  • LCD screen (128 × 64 dots)
  • Wavelength range 200 nm to 1000 nm
  • 1200 lines / mm grating optical system
  • Spectral bandwidth 4 nm
  • Wavelength repeatability 1 nm
  • Automatic 0 % transmittance
  • 100 % transmittance calibration
  • Large sample compartment accommodate 5 to 100 mm path length cuvettes
  • High accuracy with digital wavelength display
  • Data restores after sudden power cut
  • Auto setting of wavelength
  • System save test results 200 group data and 100 standard curves

Applications

  • Used in biochemistry, biotechnology, microbiology, chemistry, pharmacy, water testing, environmental and food science industries for detection of impurities, functional groups, and quality analysis and research.

Alternative Models Of Single Beam UV-Visible Spectrophotometer

Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

Single Beam UV-Visible Spectrophotometer FM-UVS-A102

  • Wavelength range: 190 nm to 1100 nm
  • Spectral bandwidth: 4 nm
  • Optical system: Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A103

  • Wavelength range: 190 nm to 1100 nm
  • Spectral bandwidth: 2 nm
  • Optical system: Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A200

  • Wavelength range: 200 to 1000 nm
  • Spectral bandwidth: 4 nm
  • Optical system: Single beam
Catalog
Single Beam UV-Visible Spectrophotometer FM-UVS-A201
  • Wavelength range: 190 to 1100 nm
  • Spectral bandwidth: 2 nm
  • Optical system: Single beam
Catalog
Single Beam UV-Visible Spectrophotometer FM-UVS-A300
  • Wavelength Range: 190 to 1100 nm
  • Spectral Bandwidth: 0.5/1/2/4/5 nm
  • Wavelength Accuracy: ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Catalog

Visible Spectrophotometer

Fison Visible Spectrophotometer features a high-resolution LCD screen, offering clear and precise monitoring of parameters. They automatically set the wavelength, ensuring precise adjustments and simplifying the measurement process for accurate results. The large sample compartment fits cuvettes with various path lengths for efficient testing. Their data restoration after a sudden power cut ensures that important test results are not lost. Our Visible Spectrophotometer have grating optical system that ensures high spectral resolution.

Visible Spectrophotometer FM-VS-A100

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Visible Spectrophotometer FM-VS-A101

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog
Visible Spectrophotometer FM-VS-A102
  • Wavelength range : 320 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Fluorescence Spectrophotometer

Fison Fluorescence Spectrophotometers offer high sensitivity and selectivity, detecting low-concentration samples with superior accuracy. They are equipped with an advanced optical system, ensuring precise detection. These units provide automatic wavelength adjustment for accurate and consistent wavelength selection. They feature a user-friendly interface, offering a digital display and control system for easy operation. Our spectrophotometers come with a compact and durable construction for long-term reliability.

Fluorescence Spectrophotometer FM-FS-A100
  • Light source : LED
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10nm
Catalog

Fluorescence Spectrophotometer FM-FS-A101

  • Light source : Xenon lamp 150 W
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10 nm
Catalog

Fluorescence Spectrophotometer FM-FS-A200

  • Light source : 150 W xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
Catalog

Double Beam UV-Visible Spectrophotometer

Fison Double Beam UV-Visible Spectrophotometers provide high-precision optical system. They provide accurate and stable measurement of absorbance and transmittance. These units feature a double beam design, simultaneously measuring the sample and reference to reduce errors and improve accuracy. They include USB and printer connectivity, enabling seamless data transfer and efficient reporting. Our spectrophotometers offer a wide wavelength range for versatile analytical applications.

Double Beam UV-Visible Spectrophotometer FM-UVS-C100
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C101
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.0 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog

Double Beam UV-Visible Spectrophotometer FM-UVS-C102

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 0.5, 1, 2 and 4 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer

Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B100

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B101
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B102
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Atomic Absorption Spectrophotometer

Fison Atomic Absorption Spectrophotometers offer high precision and sensitivity for detecting metal concentrations in various samples. They feature an advanced optical system with a high-resolution monochromator for enhanced spectral accuracy. These units provide automated sample handling, reducing manual intervention. They include a user-friendly interface and digital controls for easy operation. Our spectrophotometers deliver multiple calibration modes, allowing single and multi-element analysis to ensure versatility.

Atomic Absorption Spectrophotometer FM-AAS-A100

  • Wavelength range  : 190 to 900 nm
  • Wavelength accuracy : ≤ ±0.5 nm
  • Wavelength repeatability : ≤0.3 nm (single direction)
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A101

  • Wavelength range  : 190 to 900 nm
  • Wavelength accuracy : ± 0.15 nm
  • Wavelength repeatability : ≤ 0.04 nm
Catalog
Atomic Absorption Spectrophotometer FM-AAS-A200
  • Main specification :
    Wavelength range190 to 900 nm
    Wavelength accuracy±0.5 nm
    ResolutionTwo spectral lines of Mn at 279.5 nm and 279.8 nm, can be separated with spectral bandwidth of 0.2 nm and valley-peak energy ratio less than 30%
    Baseline stability0.005 A/30 min
    Background correctionD2 lamp background correction capability at 1A is better than 30 times
  • Light source system :
    Lamp turret2 lamps powered simultaneously (one preheated)
    Lamp current adjustment0 to 20 mA
    Lamp power supply mode400 Hz square wave pulse
  • Optical system :
    MonochromatorSingle beam, Czerny-Turner design grating monochromator
    Grating1800 lines/mm
    Focal length277 mm
    Blazed wavelength250 nm
    Spectral bandwidth0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm, automatic change
    Spectral adjustmentManual adjustment for wavelength and slit
Catalog