Our specialists will reach out shortly.

Microplate Reader FM-MPR-B100

Microplate Reader FM-MPR-B100

Microplate Reader FM-MPR-B100 has a wavelength range of 340 to 750 nm and a resolution ratio of 0.001 Abs. It provides fast and accurate measurement of 96-well plates, making it ideal for high-throughput applications. The reader is equipped with an eight-position filter wheel, with four standard filters preinstalled, allowing for a range of wavelengths. Its built-in software enables comprehensive control and data handling, ensuring ease of operation. Our microplate reader is designed to deliver consistent performance and reliability in laboratory environments.

Specifications

Light source 6V 10W Quartz halogen lamp
Wavelength Range 340 to 750 nm
Filters Four standard filters: 405 nm, 450 nm, 492 nm, 630 nm
Absorbance Range 0.000 to 4.000 Abs
Resolution Ratio 0.001 Abs
Linearity (0.2, 0) ± 1%; (2.0, 4.0) ± 2%
Wavelength Indication Error ≤ ±3 nm
Wavelength Repeatability ≤ ±1.5 nm
Repeatability (0.3, 0) ≤ 0.3%, (3.0, 4.0) ≤ 1%
Stability (0.3, 0) ≤ 0.3%, (3.0, 4.0) ≤ 1%
Accuracy (0.2, 0) ≤ ±0.005 A, (2.0, 3.0) ≤ ±1%, (3.0, 4.0) ≤ ±1.5%
Sensitivity ≥ 0.010
Channel Variation < 0.01 A (1.0 Abs standard filters)
Measurement Speed Single wavelength: <10 s/96 well, Dual wavelength: <16 s/96 well (normal mode)
Incubator Temperature Ambient +4°C to 50℃
Dimension 280 × 432 × 220 mm
Weight 10 kg

Features

  • Enables incubation temperatures up to 50℃
  • Large color screen
  • Built in self-diagnostics
  • User-friendly interface
  • Flexible plate compatibility

Applications

  • Microplate Reader FM-MPR-B100 is used in ELISA immunoassays, Protein Quantification, Cytotoxicity assays in research laboratories, educational institutions, pharmaceutical companies, etc.

Alternative Models Of Microplate Reader

Microplate reader FM-MPR-A101

  • Plate Type: 48/96 well plate
  • Wavelength Range: 400 to 850 nm
  • Standard Wavelength: 405, 450, 492, 630 nm
Catalog

Microplate reader FM-MPR-A102

  • Plate Type: 96-well plate
  • Display: 7" TFT LCD Display
  • Wavelength Range: 400 to 750 nm
Catalog

Microplate Reader FM-MPR-A103

  • Microplate type: 96/48 well plate
  • Applicable hole: Flat, V/U bottom
  • Wavelength range: 400 nm to 800 nm
Catalog
Microplate Reader FM-MPR-A104
  • Cuvette Mode: Yes
  • Microplate Type: 96/384 wells
  • Detection Mode: Absorbance
Catalog

Microplate Washer

Microplate washer FM-MPW-A100

  • Residual liquid : ≤ 1μL / well
  • Wash mode : Plate mode and Strip mode
  • Washing heads : 1 × 8 / 1 × 12
Catalog

Microplate Washer FM-MPW-A101

  • Plate type : 96 well plate
  • Residual aspiration : < 2 μl
  • Washing head : 8/12 type
Catalog