Microplate reader FM-MPR-A102 comes with 400 nm to 750 nm wide wavelength range and measures single wavelength. It offers high throughput with 3 shaking modes, fast reading speed of 5 seconds and malfunction alarm system along with 96-well multimode and bichromatic multi-channel optical system. Different detection modes like comprehensive qualitative and quantitative data-evaluation functions with cut-offs, curve-fits and transformation formulas are available. Used in drug detection and life science research, bioassay testing and quality control pharmaceutical processes.

Specifications

Plate Type 96-well plate
Display 7" TFT LCD Display
Wavelength Range 400 to 750 nm
Standard Wavelength 405, 450, 492, 630 nm
Band width 8 nm
Wavelength Accuracy ± 2 nm
Wavelength Precision ± 0.03 A
Resolution 0.001 Abs
Wavelength Linearity R ≥ 0.995
Wavelength Repeatability < 1%
Wavelength Stability < 0.005 Abs/10min
Reading Speed 5s single wavelength
Reading Range 0.000 to 4.000 Abs
Measurement System 8 Channel Optical System
Temp. Range 10°C to 35°C
Humidity Range 15% to 85%
Shaking Linear (slow, medium and high mode)
Light Source Monochromatic LED
Light Source Life More than 100000 h
Detection Method Absorbance
Detector Silicon Photodiode
Detection Modes Comprehensive Qualitative and Quantitative Data-Evaluation with Cut-Offs, Curve-Fits and Transformation Formulas
Dimension 400 × 310 × 169 mm
Power 80 W
Power Supply AC 100 to 240 V, 50/60 Hz
Weight 6 kg

Features

  • Can store up to 1200 results for 96-well plate
  • 7 inch TFT LCD Display
  • 8-channel optical measuring system
  • Single wavelength detection
  • Linear shaking function at variable speed with three modes: slow, medium and high
  • Two free positions for additional filters
  • On-board software can store 55 user programmable protocols
  • LCD light source with lifespan over 100,000 hours

Applications

  • Used in drug detection and life science research, bioassay testing and quality control pharmaceutical processes.

Alternative Models Of Microplate Reader

Microplate reader FM-MPR-A101

  • Plate Type: 48/96 well plate
  • Wavelength Range: 400 to 850 nm
  • Standard Wavelength: 405, 450, 492, 630 nm
Catalog

Microplate Reader FM-MPR-A103

  • Microplate type: 96/48 well plate
  • Applicable hole: Flat, V/U bottom
  • Wavelength range: 400 nm to 800 nm
Catalog

Microplate Reader FM-MPR-A104

  • Cuvette Mode: Yes
  • Microplate Type: 96/384 wells
  • Detection Mode: Absorbance
Catalog
Microplate Reader FM-MPR-B100
  • Light source: 6V 10W Quartz halogen lamp
  • Wavelength Range: 340 to 750 nm
  • Filters: Four standard filters: 405 nm, 450 nm, 492 nm, 630 nm
Catalog

Microplate Washer

Microplate washer FM-MPW-A100

  • Residual liquid : ≤ 1μL / well
  • Wash mode : Plate mode and Strip mode
  • Washing heads : 1 × 8 / 1 × 12
Catalog

Microplate Washer FM-MPW-A101

  • Plate type : 96 well plate
  • Residual aspiration : < 2 μl
  • Washing head : 8/12 type
Catalog