Laser Particle Size Analyzer FM-LPA-A301 is an automated wet laser particle size analyzer, adopted with Mie scattering principle and converging Fourier transform optical path, designed as per ISO 13320-1:1999 standard configurations. With 86 channels and measurement range of 0.1 to 800 µm, features fully automatic testing with ultrasonic anti dry burning function and stepper motor, precision guide rail, precision controller and software system. Equipped with fully sealed fiber semiconductor laser, laser power monitoring and automatic adjustment, has mechanical center and optical center technology. Dust-proof and shockproof design with unique self-cleaning system of circulating pipeline, micro-circulation system, bubble-free design and optimized drainage system, has anti-reflective film coated sample window with sample pool of 190 to 600 ml capacity and fogging point measurement system, offers < 1 min of test speed with mis-operation protection.

Specifications

Dispersion Type Wet
Measurement Range 0.1 to 800 µm
Channel number 86
Accuracy Error <1% (Average Particle Size of National Standard Samples)
Repeatability Error 0.5% (Average Particle Size of National Standard Samples)
Light Source Imported fiber output high power semiconductor laser
λ = 635 nm
P > 10 mW
Service life > 30000 hours
Dispersion Ultrasonic Frequency 40 kHz
Dispersion Ultrasonic Power 100 W
Dispersion Ultrasonic Time Adjustable
Dispersion Stir Revolution Speed 100 to 3950 rpm (adjustable)
Dispersion Circulation Rated Flow: 0 to 10 L/min
Rated Power: 25 W
Sample Pool Self-designed boiling sample cell
Sample Pool Capacity 190 to 600 ml
Optical Path Alignment Fully automatic
Optical Path Precision 0.2 µm
Operation mode 1 button automatic software operation mode
Standard ISO 13320-1:2009
Test Speed <1 min/time
Software Running WIN 7/ WIN 10
Mis-operation protection Yes
Design Dust proof and shock proof design
Dimension (L×W×H) 840×450×430 mm
Packaging Dimension (L×W×H) 980×610×590 mm
Net Weight 30 kg
Gross Weight 55 kg

Features

  • An automated wet laser particle size analyzer with < 1 min of test speed
  • Designed as per ISO 13320-1:1999 standard configurations
  • Mie scattering principle and converging Fourier transform optical path
  • 86 channels with measurement range of 0.1 to 800 µm
  • Fully automatic testing, avoids human interference and error
  • Ultrasonic anti dry burning function, avoids ultrasonic damage without water
  • Stepper motor, precision guide rail, precision controller and software system
  • Fully sealed fiber semiconductor laser with laser power monitoring and auto-adjustment
  • Mechanical center and optical center technology, automatic optical alignment
  • Dust-proof and shockproof design with Mis-operation protection
  • Unique self-cleaning system of circulating pipeline, avoids contamination
  • Micro-circulation system, ensures next test accuracy
  • Bubble-free design, avoids bubble entering to test sample window
  • Optimized drainage system, ensures proper cleaning of residues
  • Anti-reflective film coated sample window, long lifespan
  • Sample pool of 190 to 600 ml capacity with fogging point measurement system
  • High-efficient, stable and reliable unit for accurate and repeatable results

Applications

  • Laser Particle Size Analyzer is used to determine the size and distribution of particles across cement, ceramics, medicines, paints, chemicals, catalyst, fuel, explosives, dyes, coal etc.

Accessories Optional

  • Strong anti-corrosion design
    Microinjection

Alternative Models Of Laser Particle Size Analyzer

Fison’s Laser Particle Size Analyzers provide a range of models for both wet and dry particle analysis. Designed with advanced laser diffraction technology, they measure particle sizes from 0.1 µm to 2000 µm. Each model includes high-sensitive detectors and automated operation for seamless use. Testing is fast, delivering quick and reliable results. Our analyzers offer multiple analysis modes and flexible software for detailed data processing.

Laser Particle Size Analyzer FM-LPA-A101

  • Dispersion Type: Wet and Dry
  • Measurement Range: Wet: 0.01 to 2000 µm
    Dry: 0.1 to 2000 µm
  • Accuracy Error: Wet: <1% (CRM D50)
    Dry: <1% (CRM D50)
Catalog

Laser Particle Size Analyzer FM-LPA-A202

  • Dispersion Type: Dry
  • Measurement Range: 0.1 to 1200 µm
  • Channel number: 97
Catalog

Laser Particle Size Analyzer FM-LPA-A401

  • Dispersion Type: Spray
  • Measurement Range: 0.1 to 360 µm
  • Channel number: 54
Catalog
Laser Particle Size Analyzer FM-LPA-A102
  • Principle: Laser Diffraction
  • Measurement Range: 0.1 to 1000 µm
  • Temperature Range: 15 to 35 °C
Catalog
Laser Particle Size Analyzer FM-LPA-A201
  • Dispersion Type: Dry
  • Measurement Range: 0.1 to 300 µm
  • Number of channels: 40
Catalog

Laser Particle Size Analyzer FM-LPA-A103

  • Measuring Range: Wet: 0.01μm to 2000 μm
    Dry: 0.1μm to 2000μm
  • Measurement Method: Laser diffraction principle
  • Analysis: Mie and Fraunhofer Light scattering
Catalog

Laser Particle Size Analyzer FM-LPA-A104

  • Size Range: 0.01 to 1000 µm
  • Sample Cell Capacity: 450 ml
  • Stir Speed: 0 to 3000 rpm
Catalog

Laser Particle Size Analyzer FM-LPA-A500

  • Measuring range: 0.01µm to 3000µm
  • Repeatability error: ≤0.5%(national standard substance D50 deviation)
  • Accuracy error: ≤0.5%(national standard substance D50 deviation)
Catalog