Ion Chromatography system FM-ICS-A100

Ion Chromatography system FM-ICS-A100

Ion Chromatography system FM-ICS-A100 is designed to deliver unparalleled performance in ion analysis. Column heater maintains a stable temperature for optimal performance, with a controlling accuracy of ± 0.1 °C. Integrated with dual-channel system for independent operation of cation and anion channels. This enables simultaneous detection without any interference. With its advanced features and extensive capabilities, it is the ultimate solution for high-performance in diverse analytical settings.

  •  Cutting-edge ion chromatography system
  •  Advanced eluent thermal buffer system
  •  High-pressure, low-pulse pump technology
  •  High-performance conductivity detector
  •  Temperature stability and control
  •  Self-regeneration electrolytic suppressors
  •  Built-in leakage sensors
  •  Chemically inert design
  •  Low-pressure degassing technology

Eluent Types KOH, NaOH, LiOH, MSA
Eluent Concentration Range 0.1 to 100 mM
Eluent Generator Concentration Increment 0.1 mM
Eluent Generator Flow Rate Range 0.1 to 5.0 ml/min
Eluent Generator Maximum Pressure 30 Mpa
Eluent Generator Minimum Pressure 5 Mpa
Eluent Generator Accuracy of Gradient 0.0015
Vacuum Degree -70 kPa
Vacuum Degasser Internal Volume 300 μL
Vacuum Degasser Flow Rate Maximum 10 ml/min
Degassing Efficiency 90% at 1.0 ml/min
Degassing Volume 7.5 ml
Flow Path Material Chemically inert, metal-free PEEK, compatible with aqueous eluents of pH 0 to 14 and reversed-phase solvents
Pump Type Two-piston tandem advection pump
Maximum Pressure of Pump 42 Mpa
Pump Pressure Ripple ≤0.5%
Flow Rate Range of Pump 0.001 to 9.999 mL/min
Pump Flow Precision ≤0.1%
Pump Flow Accuracy ≤0.1%
External Diameter of the Tube 1/16"
Column heater operating temperature range Ambient +5 to 60 ℃
Column heater temperature accuracy ±0.1 °C
Column heater temperature stability ≤0.1 ℃/h
Columns Supported 2, 3, 4, 5 mm ID (up to 250 mm length, with 50 mm guard column)
Conductivity Detector type Auto-range conductivity detector
Conductivity Detector Cell Volume ≤0.8 μL
Detection Range 0 to 50000 μS/cm
Conductivity Detector Resolution ≤0.0020 nS/cm
Conductivity Baseline Noise ≤0.0005 μS/cm
Conductivity Detector Electronic noise 0.02 nS
Detector Baseline Drift ≤0.005 Μs
Conductivity Detector Maximum Pressure 10 Mpa
Operating Temperature Range Ambient +5 ℃ to 60 ℃
Controlling Temperature Accuracy ±0.01 ℃
Temperature Compensation 1.7 % / ℃
Maximum Pressure Handling 10.0 MPa
Linear Range of Conductivity Measurement ≥10 3
Instrument Linearity for Conductivity ≥0.999
Quantitative Repeatability in Conductivity ≤0.5%
Qualitative Repeatability in Conductivity ≤0.2%
Minimum Detectable Concentration (Cl-) ≤0.0004 µg/mL
Minimum Detectable Concentration (Li+) ≤0.0001 µg/mL
Suppressor type Self-Regeneration electrolytic micro-membrane
Suppressor maximum pressure 6 MPa
Suppressor void volume < 40 μL (4 mm), < 15 μL (2 mm)
Power 350 W
Exterior dimension (L × W × H) 500 × 500 × 760 mm
Net Weight 48 Kg
Gross Weight 73 Kg

Ion Chromatography system is widely used across environmental analysis, pharmaceuticals and biotechnology, food and beverage, chemicals, petrochemicals, water treatment, healthcare and clinical laboratories, agriculture, etc.