Ion Chromatography system FM-ICS-A100 is designed to deliver unparalleled performance in ion analysis. Column heater maintains a stable temperature for optimal performance, with a controlling accuracy of ± 0.1 °C. Integrated with dual-channel system for independent operation of cation and anion channels. This enables simultaneous detection without any interference. With its advanced features and extensive capabilities, it is the ultimate solution for high-performance in diverse analytical settings.
Specifications
Eluent Types | KOH, NaOH, LiOH, MSA |
Eluent Concentration Range | 0.1 to 100 mM |
Eluent Generator Concentration Increment | 0.1 mM |
Eluent Generator Flow Rate Range | 0.1 to 5.0 ml/min |
Eluent Generator Maximum Pressure | 30 Mpa |
Eluent Generator Minimum Pressure | 5 Mpa |
Eluent Generator Accuracy of Gradient | 0.0015 |
Vacuum Degree | -70 kPa |
Vacuum Degasser Internal Volume | 300 μL |
Vacuum Degasser Flow Rate | Maximum 10 ml/min |
Degassing Efficiency | 90% at 1.0 ml/min |
Degassing Volume | 7.5 ml |
Flow Path Material | Chemically inert, metal-free PEEK, compatible with aqueous eluents of pH 0 to 14 and reversed-phase solvents |
Pump Type | Two-piston tandem advection pump |
Maximum Pressure of Pump | 42 Mpa |
Pump Pressure Ripple | ≤0.5% |
Flow Rate Range of Pump | 0.001 to 9.999 mL/min |
Pump Flow Precision | ≤0.1% |
Pump Flow Accuracy | ≤0.1% |
External Diameter of the Tube | 1/16" |
Column heater operating temperature range | Ambient +5 to 60 ℃ |
Column heater temperature accuracy | ±0.1 °C |
Column heater temperature stability | ≤0.1 ℃/h |
Columns Supported | 2, 3, 4, 5 mm ID (up to 250 mm length, with 50 mm guard column) |
Conductivity Detector type | Auto-range conductivity detector |
Conductivity Detector Cell Volume | ≤0.8 μL |
Detection Range | 0 to 50000 μS/cm |
Conductivity Detector Resolution | ≤0.0020 nS/cm |
Conductivity Baseline Noise | ≤0.0005 μS/cm |
Conductivity Detector Electronic noise | 0.02 nS |
Detector Baseline Drift | ≤0.005 Μs |
Conductivity Detector Maximum Pressure | 10 Mpa |
Operating Temperature Range | Ambient +5 ℃ to 60 ℃ |
Controlling Temperature Accuracy | ±0.01 ℃ |
Temperature Compensation | 1.7 % / ℃ |
Maximum Pressure Handling | 10.0 MPa |
Linear Range of Conductivity Measurement | ≥10 3 |
Instrument Linearity for Conductivity | ≥0.999 |
Quantitative Repeatability in Conductivity | ≤0.5% |
Qualitative Repeatability in Conductivity | ≤0.2% |
Minimum Detectable Concentration (Cl-) | ≤0.0004 µg/mL |
Minimum Detectable Concentration (Li+) | ≤0.0001 µg/mL |
Suppressor type | Self-Regeneration electrolytic micro-membrane |
Suppressor maximum pressure | 6 MPa |
Suppressor void volume | < 40 μL (4 mm), < 15 μL (2 mm) |
Power | 350 W |
Exterior dimension (L × W × H) | 500 × 500 × 760 mm |
Net Weight | 48 Kg |
Gross Weight | 73 Kg |
Features
Applications
Fison Analytical HPLC Systems are designed for precise and efficient liquid chromatography, offering reliable performance for various applications. They feature an adjustable flow rate range, ensuring optimal flow control for different sample types. These systems provide user-friendly interface for simple operation and boost productivity. They offer robust pump designs for reliable, stable performance. Our units include integrated software system for seamless digital documentation.
Labtron Liquid Chromatography are designed for multi-component purification with high specificity, sensitivity and stability. They combine liquid chromatograph with mass spectrometer for improved identification accuracy. Their design minimizes contamination and background noise for operational ease. They are equipped with pumps for accurate and precise flow rate control. Our Liquid Chromatography feature wider dynamic range of detectors for data reproducibility and reliability.
Fison GC-MS includes highly sensitive detection systems that analyze trace compounds at levels as low as ppb or ppt. They support various analysis modes, such as selected ion monitoring (SIM) for targeted analyses. Their integration with autosamplers ensures fast and consistent sample handling for large batches. The vast libraries, such as NIST and Wiley, enable the accurate identification of unknown compounds through spectral matching. These are capable of detecting a wide range of concentrations, from ultra-trace levels to high concentrations, making them ideal for diverse sample types. Our GC-MS are equipped with sensitive detectors like quadrupoles, ion traps, or (TOF) systems for advanced mass analysis.