Gas chromatography FM-GC-A100

Gas chromatography FM-GC-A100

Gas chromatography FM-GC-A100 controls temperatures precisely from RT + 5°C to 450°C. It features a high-precision gas flow control system (EPC) for accuracy. It includes self-protection for gas circuit failure and automatic ignition. Innovative sampler design prevents sample sticking to the surface. Various injection methods like headspace sampling, thermal desorption analysis, and liquid automatic sampling are enabled. It can start analyses automatically at set times. The unit offers a user-friendly interface with a color widescreen and unique touch keys. Its modular design allows easy upgrades and compatibility with detectors such as FID, TCD, ECD, FPD, and NPD.

  •  Gas chromatography offers efficiency, stability, and user-friendly operation
  •  16-phase temperature program at 40°C/min
  •  Equipped with Brain Chrom workstation for data processing
  •  Built-in Modbus/TCP server for easy connection to DCS
  •  Injection types include packed column injection and capillary column injection
  •  Flow setting range of 0 to 1000 ml/min
  •  Sampling valve can be equipped with multiple imported automatic control valves
  •  Supports 1 to 4 inlets, allowing up to 3 capillary column inlets for injection

Oven
Temperature RangeRT+5 to 450°C
Temperature Accuracy≤ ± 0.01℃
Temperature. Program16-phase
Maximum Heating Rate40℃/min
Time Range0 to 900.9 min
Hydrogen Flame Ionization Detector ( FID )
Temperature Range450°C
Detection limit≤ 5 × 10-12g/s (100 ng/ul n- hexadecane – isooctane solution)
Base line drift≤ 2 × 10-13 A /30 min
Base line noise3 × 10-14A
Linear Range≥10-7
Injection MethodCapillary column split / splitless sampling , Packed Column sampling , valve sampling , gas/liquid automatic sampling system ,etc.
Inlet1 to 4 , up to 3 capillary column inlets
Injection TypePacked column injection , capillary column injection
Flow range0 to 1000 ml/min
Control AccuracyPressure : 0.01 Kpa , Flow : 0.01 ml / min
Maximum Split Ratio1 : 999
Force DetectorAccuracy : < 2 % of full scale
Repeatability : 0 .05 KPa
Range : 0 to 0.6 Mpa
Flow sensorsAccuracy : < 5 % of full scale
Repeatability : 0 .5K Pa
Sampling ValveCan sequentially operate multiple imported automatic control valves
Power SupplyAC 220 V ± 10 %, 50/60 Hz.
Packaging Dimension ( W × D × H )750 × 710 × 720 mm
Gross Weight70 Kg

Gas chromatography is employed across diverse sectors for applications such as environmental monitoring, petrochemical analysis, pharmaceutical research, food and beverage testing, forensic investigations, chemical research, clinical diagnostics, material analysis, quality control, and research and development

FID Detector
Chromatography workstation software
Capillary Sampler

Accessories Name Specification
Sample Injection System
Thermal Conductivity meter(TCD) Sensitivity : > 5000 mv.ml /mg
( 50 mg /ml toluene -benzene solution )
Temperature : 400°C
Baseline drift : ≤ 0.1 m V /30 min
Linear range : ≥ 105 ( ± 10 % )
Electron Capture Detector ( ECD ) Detection limit : ≤ 1 × 10 -14 g / ml
( Sample : n -hexadecane – δ 666 )
Linear Range : ≥ 10 4
Flame Photometric Detector ( FPD ) Detection limit : ≤5 × 10 -12g/s (S of 10 ng/ul methyl parathion-ethanol solution)
Detection limit : ≤ 4×10 -12 (P of 10 ng/ul methyl parathion-ethanol solution)
Linear range (S): ≥ 103
Linear range ( P) : ≥ 10 4
Nitrogen and Phosphorus Detector ( NPD ) Detection limit : ≤ 1 × 10 -12g/s(Azobenzene)
Detection limit : ≤ 1 × 10-12 (Marla sulfur phosphorous)
Linear range : ≥ 10 3