FTIR Spectrometer FM-FTI-A102 is built in with intellectual property and functions with spectral range of 7800 to 350 cm-1 and can deliver high SNR up to 20000:1. The instrument obtains the best balance between convenient operation and intelligence, low operation and advance performance and maintenance cost. We will use gas cell to analysis the gas sample. The light path for the gas cell is 100 mm and diameter is 40 mm, so the estimate volume is 125 cm3. To ensure detection sensitivity, reflecting corner cube mirrors are coated with gold for maximum light throughput. Equipped with detection sensitivity with multilayer Ge coated KBr beam splitter specification, aluminum based cast design layout structure and high intensity, long lasting air cooled infrared source. The electronic system is designed to meet electromagnetic compatibility requirements and CE certification.
Specifications
Interferometer | Cube-corner Michelson interferometer |
Beam Splitter | Multilayer Ge coated KBr |
Detector | Room temperature DLATGS module (standard) |
IR Source | High intensity, long lifetime, air-cooled IR source |
Wavenumber Range | 7800 cm-1 to 350 cm-1 |
Resolution | 0.85 cm-1 |
Signal To Noise Ratio | Better than 20,000:1 (RMS value, at 2100 cm-1 to 2000 cm-1 or 2100 cm-1 to 2200 cm-1, Resolution: 4 cm-1, Detector: DLATGS, 1 minute data collection |
Wavenumber Accuracy | ± 0.01 cm-1 |
Scanning Speed | Microprocessor control, different scanning speed selectable |
Software | mainFTOS Suite software workstation, compatible to all version Window OS |
Communication | Ethernet interface (standard) |
Data Output | Standard data format, report generation and output |
Status Diagnosis | Power on self-check, real-time temperature and humidity monitoring and reminders |
Environment Condition | Temperature: 10°C to 30°C, Humidity: less than 70 % |
Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
Dimensions | 520×435×255 mm |
Weight | 24 kg |
Features
Applications
Accessories
Accessories Optional
Sr. No | Accessories Name | Unit |
1. | Diffuse/Specular Reflectance | 1 set |
2. | Horizontal ATR for Liquid and Powder (ZnSe crystal) | 1 set |
3. | Single reflection ATR (Diamond crystal) | 1 set |
4. | Single reflection ATR (ZnSe crystal) | 1 set |
5. | Gas cell (with KBr window plates) | 1 Piece |
6. | Demountable Liquid cell (with KBr window plates) | 1 Piece |
7. | KBr hydraulic press 15 T (including die set) | 1 set |
8. | Spare die set for the hydraulic press | 1 set |
9. | Mortar and pestle ¢ 50 | 1 set |
10. | Mortar and pestle ¢ 70 | 1 set |
11. | Dehumidifier (50 L) | 1 set |
12. | KBr Window plate (ϕ 25×4, for liquid cell) | 1 Piece |
13. | CaF2 Window plate (ϕ 25×4, for liquid cell) | 1 Piece |
14. | BaF2 Window plate (ϕ 25×4, for liquid cell) | 1 Piece |
15. | KBr powder spectroscopic grade (10 g/bottle) | 1 bottle |
16. | KBr powder spectroscopic grade (25 g/bottle) | 1 bottle |
17. | Window plate polishing kit | 1 Piece |
18. | FDA 21 CFR Part11 | 1 kit |
19. | WIFI wireless connection module | 1 kit |
Advance Tools
Sr. No | Advance Tools Name | Description | |
1. | Internet + Detection instrument design with multiple communication options: | I. | Adapting to “Internet+ detection” instrument development trend |
II. | WIFI wireless communication as an option | ||
III. | Data cloud computing | ||
IV. | Ethernet interface as standard supply for data transfer | ||
V. | Remote operation and maintenance | ||
VI. | Setting up a basic platform for interconnected tests | ||
2. | Real-time Diagnosis of instrument status | I. | Instrument’s communication, performance, and working status is monitored by real-time |
3. | Optional temperature stabilized, high sensitivity DLATGS detector module. | I. | Ensures high sensitivity, stability and good reproducibility of IR spectral analysis. Provides stable detector response |
II. | Provides stable detector response |
Software Workstation
Sr.No | MainFTOS Suite Software | Function |
1. | All version Windows OS compatible | Windows XP, Windows 7, Windows 8, Windows 8.1 and Windows 10 (32 bits and 64 bits) |
2. | Modular platform design | Data collection, processing and analysis, report print out functions and different special software functions module options |
3. | FDA CFR 21 Part 11 Compliance | Access control, authority assignment, audit trial, digital signature |
4. | Automatic software updating | Getting the latest software version from the updating center |
5. | Real-time instrument status diagnosis | Real-time monitor of working status, specifications and communication status |
6. | Secondary development library | Providing C++ and C development sample code for different application development |
7. | Specialized IR libraries | Providing various specialized IR libraries |
8. | Touch control operation | Satisfying Window 10’s touch control function |
Fison FTIR spectrometers are designed for precise molecular analysis across various fields. They deliver high spectral resolution, ensuring detailed and accurate spectral data. These units include multiple detector options for high sensitivity uses. They provide a user-friendly software interface, enabling easy data analysis, report generation, and spectrum comparison. Our spectrometers feature USB & Wi-Fi connectivity, guaranteeing seamless data transfer and remote operation.
Fison UV Visible Spectrometer has easy power supply integration, allowing smooth operation with minimal setup. The spectrometer offers customizable optical resolution for users to adjust settings based on their specific requirements. This ensures accurate bandwidth calculation for precise analysis, enhancing overall measurement reliability. They feature high-performance trigger modes, providing efficient control for accurate results. Our UV-visible spectrometer has enhanced peak wavelength detection; it guarantees improved accuracy in identifying key wavelengths.
Fison Flame Atomic Absorption Spectrometer has a wide wavelength range allowing precise detection of various metal elements. They have an Adjustable Spectral Bandwidth that enables optimization of resolution and sensitivity. These have a Stable and Efficient Flame Atomizer that provides uniform sample introduction ensuring consistent results. They have Automatic Lamp Selection that supports multiple lamps with automatic alignment for multi-element analysis. These have Built-in Safety Features including flame monitoring, gas pressure regulation, and an automatic gas shutoff system for safety. Our Spectrometer has an easy-to-use touchscreen or software for method setup, calibration, and data analysis.