Class II Biosafety Cabinet FM-BSC-A202

Class II Biosafety Cabinet FM-BSC-A202

Class II Biosafety Cabinet FM-BSC-A202 is a Class II type A2 safety level 2 enclosed cabinet unit with 70% of the ULPA filtered air recirculated through cabinet and 30% discharged through an exhaust ULPA filter to environment. Engineered specifically for laboratory operations that require user and product protection. Operates with a negative air pressure for personnel protection and HEPA filtered laminar airflow for product protection. The 40 W UV lamp with 253.7 nm emission serves purpose of attaining effective sterilization, also equipped with remote control functions, for convenient working operations. Suitable for work with microbiological research in absence of volatile or toxic chemicals and radionuclide.

  •  Class II, A2 type of microbiological safety cabinet
  •  Facilitates personnel, product and environment protection
  •  Digital LCD display for easy monitoring of all parameters
  •  Ergonomically sized control panel improves user interface
  •  Airflow system: 70% air recirculation, 30% air exhaust
  •  Time reserve and power lock function
  •  ULPA filter life and UV life indicator
  •  Automatic air speed adjustable with filter block
  •  304 grade stainless steel work table for operation surrounded by negative pressure
  •  Waterproof sockets positioned at side panels avails use of small devices in cabinet
  •  Reserved access for water and gas tap at cabinet side panel
  •  Emission of 253.7 nm from UV lamp for high efficient decontamination
  •  Motored front window for convenient, one hand operation
  •  Two-layer laminated toughened glass front window >5mm, anti UV layer
  •  Remote controlled operation realized at 6 m distance from cabinet, protecting feature to user in course of emergency
  •  Foot switch to adjust the height of the front window
  •  Audio and visual alarm (filter replacement, window over height, abnormal air flow velocity)

Type Class II, A2 type
Filter Type ULPA Filter
Filter Quantity 2 ULPA filters
Filter efficiency ULPA Filter: 99.9995% efficiency at 0.12 µm
Inflow velocity 0.53 ± 0.025 m/s
Down flow velocity 0.33 ± 0.025 m/s
UV lamp 40 W ×1
UV Lamp emission 253.7 nm
Illuminating LED lamp 16 W ×2
Illumination ≥ 1000 Lux
Power consumption 900 W
Noise level ≤ 60 dB
Waterproof socket 500 W ×2
Front window Two-layer laminated toughened glass, 5 mm
Work surface height 750 mm
Tested Opening Safety height ≤ 200 mm
Max opening of front window 500 mm
Internal dimension (W×D×H) 1300×600×660 mm
External dimension (W×D×H) 1500×750×2250 mm
Display LCD display
Display parameter status Exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time
Control system Microprocessor
Airflow system 70% air recirculation, 30% air exhaust
Visual and audio alarm Filter replacement, front window at unsafe height, abnormal air flow velocity
Water and gas tap Reserved at side cabinet panel
Caster Foootmaster caster
Clean Level ISO 5 Class 100
Chamber Material (work table) 304 stainless steel
Chamber Material (body) Cold-rolled steel with anti-bacteria powder coating
Power supply 221 V±10%, 50/60 Hz, 100 V±10%, 60 Hz
Packaging dimension with base stand (W×D×H) 1630×1000×1820 mm
Gross weight 316 kg

The Class II type A2 Biosafety Cabinet helps in protecting the user, the environment, and the experimental material in use. It is the most widely used type of cabinet in biomedical and microbiological laboratories.

Accessories no Accessories name
1.        LED lamp 2 pcs
2.        UV lamp
3.        Base stand
4.        Remote control
5.        Foot switch
6.        Drain valve
7.        2 Waterproof sockets

Accessories No. Name
1 Water Tap
2 Gas Tap