Gas chromatography FM-GC-A100 controls temperatures precisely from RT + 5°C to 450°C. It features a high-precision gas flow control system (EPC) for accuracy. It includes self-protection for gas circuit failure and automatic ignition. Innovative sampler design prevents sample sticking to the surface. Various injection methods like headspace sampling, thermal desorption analysis, and liquid automatic sampling are enabled. It can start analyses automatically at set times. The unit offers a user-friendly interface with a color widescreen and unique touch keys. Its modular design allows easy upgrades and compatibility with detectors such as FID, TCD, ECD, FPD, and NPD.
Oven Temperature Range | RT+5 to 450°C |
Oven Temperature Accuracy | ≤ ± 0.01℃ |
Oven Temperature Program | 16-phase |
Oven Maximum Heating Rate | 40℃/min |
Oven Time Range | 0 to 900.9 min |
FID Temperature Range | 450°C |
FID Detection Limit | ≤ 5 × 10⁻¹² g/s (100 ng/µl n-hexadecane – isooctane solution) |
FID Baseline Drift | ≤ 2 × 10⁻¹³ A / 30 min |
FID Baseline Noise | 3 × 10⁻¹⁴ A |
FID Linear Range | ≥ 10⁻⁷ |
Injection Method | Capillary column split/splitless sampling, Packed Column sampling, valve sampling, gas/liquid automatic sampling system, etc. |
Injection Inlet | 1 to 4, up to 3 capillary column inlets |
Injection Type | Packed column injection, capillary column injection |
Flow Control Range | 0 to 1000 ml/min |
Flow Control Accuracy | Pressure: 0.01 KPa, Flow: 0.01 ml/min |
Flow Maximum Split Ratio | 1:999 |
Force Detector Accuracy | < 2 % of full scale |
Force Detector Repeatability | 0.05 KPa |
Force Detector Range | 0 to 0.6 MPa |
Flow Sensor Accuracy | < 5 % of full scale |
Flow Sensor Repeatability | 0.5 KPa |
Sampling Valve Operation | Can sequentially operate multiple imported automatic control valves |
Power Supply | AC 220 V ± 10 %, 50/60 Hz |
Packaging Dimensions (W × D × H) | 750 × 710 × 720 mm |
Weight | 70 Kg |
FID Detector
Chromatography workstation software
Capillary Sampler
Accessories Name Specification Sample Injection System Thermal Conductivity meter(TCD) Sensitivity : > 5000 mv.ml /mg ( 50 mg /ml toluene -benzene solution ) Temperature : 400°C Baseline drift : ≤ 0.1 m V /30 min Linear range : ≥ 105 ( ± 10 % ) Electron Capture Detector ( ECD ) Detection limit : ≤ 1 × 10 -14 g / ml ( Sample : n -hexadecane – δ 666 ) Linear Range : ≥ 10 4 Flame Photometric Detector ( FPD ) Detection limit : ≤5 × 10 -12g/s (S of 10 ng/ul methyl parathion-ethanol solution) Detection limit : ≤ 4×10 -12 (P of 10 ng/ul methyl parathion-ethanol solution) Linear range (S): ≥ 103 Linear range ( P) : ≥ 10 4 Nitrogen and Phosphorus Detector ( NPD ) Detection limit : ≤ 1 × 10 -12g/s(Azobenzene) Detection limit : ≤ 1 × 10-12 (Marla sulfur phosphorous) Linear range : ≥ 10 3