Our specialists will reach out shortly.

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D200 Catalog

Overview

Double Beam Scanning UV-Visible Spectrophotometer FM-UVS-D200 is a high-performance unit having 190 to 900 nm of wavelength range with variable spectral bandwidth from 0.1 to 5nm, selected by a continuous variable slit. Features Czerny-Turner monochromator and photo multiplier tube detector with electronic control system ensures high stability and low background noise. Compact design with fixed position sample, has tungsten and deuterium lamp as light source and USB interface to connect with PC.

Specifications :

Wavelength range 190 to 900 nm
Spectral bandwidth Continuous slit 0.1 to 5.0 nm with 0.1 nm interval
Optical system Double beam
Wavelength accuracy ±0.3 nm
Wavelength repeatability ≤0.1 nm
Scanning speed Selectable
Photometric range -4 to 4 Abs
Photometric accuracy ±0.002 A (0 to 0.5vA), ±0.004vA (0.5 to 1.0 A), ± 0.3% T (0 to 100% T)
Photometric reproducibility ±0.001 A (0 to 0.5 A)
Noise ± 0.0004 A (500 nm) 30 min warm-up
Light source Tungsten lamp and Deuterium lamp
Stray light ≤ 0.01%T (220 nm Nal, 340 nm NaNO2)
Baseline flatness ±0.001 A (200 to 850 nm)
Baseline stability ± 0.0008 A/h (500 nm, 0 Abs), 2hr warm-up
Standard Sample holder Fixed sample position
Detector Photo multiplier tube
Monochromator Czerny-Turner
Wavelength correction Automatic
Interface USB
Power supply AC 120 to 230 V, 50/60 Hz
Dimension (W×D×H) 545×580×270 mm
Weight 43 kg

Features :

  • A high-performance unit with 190 to 900 nm of wavelength range
  • Variable spectral bandwidth from 0.1 to 5nm, selected by a continuous variable slit
  • Czerny-Turner monochromator and photo multiplier tube detector
  • Automatic wavelength correction with ± 0.3 nm wavelength accuracy
  • Tungsten and deuterium lamp as light source, easy replacement and maintenance
  • USB interface to connect with PC for easy data processing and analysis
  • A high stable and reliable unit with low background noise

Applications :

Double Beam Scanning UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across clinical and research laboratories.

Accessories Optional :
  • Sipper PumpConstant Temperature Cell HolderPeltierAdjustable Angle Solid Sample HolderSolid Sample HolderStandard Sample HolderAutomatic 8 Position Cell ChangerUniversal 5 to 100 mm Path Length Cell HolderMicro Cell HolderUltra-micro cell holderSpecula Reflectance AccessoriesIntegrating SphereTest Tube Holder 13 to 16 mm VariableShort Path-length Cell HolderSoftware