Analytical HPLC System FM-AHS-B100 offers an adjustable flow rate setting range from 0.001 to 10.000 mL/min, allowing precise control over sample flow. It provides a user-friendly interface to enhance operational productivity. This unit features a mainstream split pump design with a custom one-piece check valve for improved flow accuracy. It delivers dynamic flow compensation to maintain accurate flow stability. Our HPLC system supports dual wavelength detection and FPGA valve control for reliable analysis.
System Qualitative Repeatability | less than or equal to.0.2% |
System Quantitative Repeatability | less than or equal to. 0.4% |
Flow Pump Flow Rate Setting Range | 0.001 to 10.000 mL/min |
Flow Pump Setting Step | 0.001 mL/min |
Flow Pump Pressure Range | 0 to 45 Mpa |
Flow Pump Pressure Pulsation | 0.1 MPa (10 MPa, C18, methanol 1 mL/min) |
Flow Pump Flow Rate Set Error | ±0.2% |
Flow Pump Flow Rate Stability | RSD less than or equal to 0.06% |
Flow Pump Gradient Error | ±1% |
Flow Pump Plunger Cleaning | Standard equipped with active online plunger cleaning module |
Column Oven Temperature Control Range | 4 to 90 °C |
Column Oven Temperature Stability | ±0.02 °C |
Column Oven Temperature Setting Resolution | 0.1 °C |
Column Oven Preheat | Built-in 1-way preheat module cooling module minimum temperature |
Column Oven Preheat Room Temperature | –10 °C |
Autosampler Injection Volume Repeatability | less than 0.5% RSD |
Autosampler Linearity | greater than 0.9999 |
Autosampler Cross Contamination | less than 0.002% |
Autosampler Injected Volume Accuracy Error | ±1% |
Autosampler Number of Samples | 120 (2×60, 2 mL) |
Autosampler Syringe Specifications | Standard: 500 μL Optional: 250 μL, 1000 μL, 2500 μL |
Autosampler Quantification Loop | Standard: 100 μL Optional: 10 μL, 20 μL, 50 μL, 200 μL |
Autosampler Minimum Sample Refrigeration Temperature | 4 °C |
Autosampler Controlled Sample Refrigeration Temperature Range | 4 to 30 °C |
Autosampler Injection Needle Cleaning | Internal and external needle cleaning and blowing dry |
Autosampler Working Mode | XYZ positioning, with puncture function |
Autosampler Injection Volume | 1 to 100 μL |
Working Power Supply | 220V, 50HZ |
Ambient Temperature | 10 to 40℃ |
Relative Humidity | 20 to 85% |
Power Supply | 110V to220V, 50Hz/60Hz AC |
Pump Dimension | 620 × 525 × 465 mm |
Column Oven Dimension | 770 × 620 × 640 mm |
Autosampler Dimension | 770 × 620 × 640 mm |
Pump Weight | 25.2 kg |
Column Oven Weight | 34 kg |
Autosampler Weight | 46 kg |
Quaternary pump
PDA detector