Our specialists will reach out shortly.

Automatic Bomb Calorimeter FM-ABC-B100

Automatic Bomb Calorimeter FM-ABC-B100

Automatic Bomb Calorimeter FM-ABC-B100 supports an energy measurement range of 0 to 50,000J, ensuring versatile testing capabilities. This is raised and lowered automatically for better operation, increasing convenience and efficiency. It features a semiconductor water tank for precise temperature control with low power and noise. Our Calorimeter includes pressure monitoring to ensure safe and stable operation.

Specifications

Energy Measurement Range 0 to 50000J
Heat Capacity Stability ≤0.2% within 12 months
Measurement Consistency (RSD) ≤0.08%
Bomb Volume 250ml
Calorimeter Type Isoperibol
Bomb Washing Manual
Maximum Bomb Pressure 20MPa
Bomb Identity Yes
Gas Requirement 99.5% Oxygen
Analysis Time Fast mode <10min
Standard mode<12min
Precision mode <14min
Repeatability (RSD) (Using 1g Benzoic Acid) ≤0.05%
Bucket Filling Automatic
Independent Bucket and Jacket Water System Yes
Stirring Method Propeller
Ambient Temperature 10 to 35°C
Average Temperature Increase 2℃
Temperature Measurement PT1000
Working Temperatures 35℃
Cooling Method Refrigerating Device
Network Yes
Advance Calculation Yes
Analysis Report Yes
Statistics Report Yes
System Monitor Yes
Power Consumption 600W
Power Supply AC 220V, 50/60Hz
Dimensions (L×W×H) 428 × 565 × 485 mm
Weight 50 kg

Features

  • Automatic oxygen filling system
  • Reliable self-diagnostic function
  • User-friendly calibration interface
  • Automatic pipeline flushing
  • Advanced data analysis capabilities

Applications

  • Automatic Bomb Calorimeter FM-ABC-B100 is used in laboratories for accurate calorimetric testing of fuel, food, and chemical samples. It applies to industries such as energy, environmental research, and quality control.

Alternative Models Of Automatic Bomb Calorimeter

Automatic Bomb Calorimeter FM-ABC-A100

  • Calorimeter type: Isoperibol
  • Temperature range: 5℃ to 40℃
  • Measuring range: 5 MJ/kg to 40 MJ/kg (Can be expanded 0 to 50000J)
Catalog

Heat Flow Calorimeter

Heat Flow Calorimeter FM-HFC-A100

  • Diameter : DN15
  • Min. Flow qmin : 0.03 m³/h
  • Quantity of Flow (qp) : 1.5 m³/h
Catalog

Heat Flow Calorimeter FM-HFC-A101

  • Diameter : DN20
  • Min. Flow qmin : 0.05 m³/h
  • Quantity of Flow (qp) : 2.5 m³/h
Catalog
Heat Flow Calorimeter FM-HFC-A102
  • Diameter : DN25
  • Min. Flow qmin : 0.07 m³/h
  • Quantity of Flow (qp) : 3.5 m³/h
Catalog

Differential Scanning Calorimeter

Fison offers high-performance Differential Scanning Calorimeters for precise thermal analysis. These instruments operate on the principle of measuring heat flow differences between a sample and a reference under controlled temperature conditions. With a temperature range of RT to 550°C, they provide accurate measurements of heat flow and temperature transitions. Advanced temperature control, high sensitivity, and user-friendly interfaces make them well-suited for diverse applications

Differential Scanning Calorimeter FM-DSC-A100
  • Temperature range : RT to 550°C
  • Thermal resolution : 0.001°C
  • Temperature variations : ± 0.001°C
Catalog