Our specialists will reach out shortly.

Atomic Absorption Spectrophotometer FM-AAS-A200

Atomic Absorption Spectrophotometer FM-AAS-A200

Atomic Absorption Spectrophotometer FM-AAS-A200 is an air-acetylene flame-only system with a true double-beam design for fast start-up and exceptional long-term stability. Features cutting-edge fiber optics to maximize light throughput for improved detection limits, as well as two-lamp mount, and automated flame and burner assembly optimization for enhanced productivity. Fitted out with single beam, Czerny-Turner design grating monochromator 1800 lines/mm, D2 lamp background correction capability and Cu, Mn, Hg hollow cathode lamps for elemental analysis.

Specifications

Wavelength Range 190 to 900 nm
Wavelength Accuracy ±0.5 nm
Resolution Two spectral lines of Mn at 279.5 nm and 279.8 nm, separable with spectral bandwidth of 0.2 nm and valley-peak energy ratio < 30%
Baseline Stability 0.005 A/30 min
Background Correction D₂ lamp background correction, capability at 1A is better than 30 times
Lamp Turret 2 lamps powered simultaneously (one preheated)
Lamp Current Adjustment 0 to 20 mA
Lamp Power Supply Mode 400 Hz square wave pulse
Monochromator Single beam, Czerny-Turner design grating monochromator
Grating 1800 lines/mm
Focal Length 277 mm
Blazed Wavelength 250 nm
Spectral Bandwidth 0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm (automatic change)
Spectral Adjustment Manual adjustment for wavelength and slit
Burner 10 cm single-slot all-titanium burner
Spray Chamber Corrosion-resistant all-plastic spray chamber
Nebulizer High-efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7 ml/min
Position Adjustment Manual adjustment for vertical, horizontal positions, and burner rotation angle
Gas Line Protection Fuel gas leakage alarm
Detector R928 Photomultiplier with high sensitivity and wide spectral range
Electronic & Micro-computer System Automatic adjustment of light source power, light energy, and negative high-voltage auto-balance
Display Mode LED display of energy, measurement values, and direct concentration reading
Read Mode Transient, time average, peak height, peak area, integral time selectable (0.1 to 19.9 s)
Scale Expansion 0.1 to 99
Data Processing Mode Automatic calculation of mean, standard deviation, and relative standard deviation (Reporting range: 1 to 99)
Measurement Mode Automatic curve fitting with 3 to 7 standards, sensitivity auto-correction
Result Printing Measurement data, working curve, signal profile, and analytical conditions
Instrument Self-check Checks current status of each function key
Characteristic Concentration of Cu ≤0.025 mg/L
Detection Limit of Cu ≤0.006 mg/L
Power Supply AC 220 V, 50 Hz
Dimension 1020 × 490 × 540 mm
Weight 80 kg

Features

  • Air-acetylene flame and titanium burner atomization alongwith flame atomizer nebulizer
  • Built-in microprocessor with auto-control and data processing functions
  • Bright LED display of energy and measurement values, concentration direct reading
  • D2 lamp background correction capability
  • Simultaneously powered 2 turret hollow cathode lamps (one preheating)
  • Spectral bandwidth of 0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm
  • Manual adjusting mechanism for altering rotation angle of burner
  • R928 Photomultiplier with high sensitivity and wide spectral range
  • Light energy and negative high-voltage auto-balance
  • Results printed as measurement data, working curve, signal profile and analytical conditions

Applications

  • Used in clinical analysis of metals in biological fluids and tissues such as whole blood, plasma, urine, saliva, brain tissue, liver, hair, muscle tissue, semen, in some pharmaceutical manufacturing processes, minute quantities of a catalyst that remain in final drug product, and analyzing water for its metal content.

Accessories Optional

  • 1.    Air Compressor
    2.    Hydride Vapor Generator
    3.    Hydride Vapor Generator (Peristaltic Pump Type)
    4.    High-Efficiency Glass Nebulizer
    5.    Water Chiller

Alternative Models Of Atomic Absorption Spectrophotometer

Fison Atomic Absorption Spectrophotometers offer high precision and sensitivity for detecting metal concentrations in various samples. They feature an advanced optical system with a high-resolution monochromator for enhanced spectral accuracy. These units provide automated sample handling, reducing manual intervention. They include a user-friendly interface and digital controls for easy operation. Our spectrophotometers deliver multiple calibration modes, allowing single and multi-element analysis to ensure versatility.

Atomic Absorption Spectrophotometer FM-AAS-A100

  • Wavelength range : 190 to 900 nm
  • Wavelength accuracy: ≤ ±0.5 nm
  • Wavelength repeatability: ≤0.3 nm (single direction)
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A101

  • Wavelength range : 190 to 900 nm
  • Wavelength accuracy: ± 0.15 nm
  • Wavelength repeatability: ≤ 0.04 nm
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A201

  • Wavelength Range: 190 to 900 nm
  • Wavelength Accuracy: ± 0.25 nm
  • Resolution: Two spectral lines of Mn at 279.5 nm and 279.8 nm, separable with a spectral bandwidth of 0.2 nm and valley-peak energy ratio < 30%
Catalog

Visible Spectrophotometer

Fison Visible Spectrophotometer features a high-resolution LCD screen, offering clear and precise monitoring of parameters. They automatically set the wavelength, ensuring precise adjustments and simplifying the measurement process for accurate results. The large sample compartment fits cuvettes with various path lengths for efficient testing. Their data restoration after a sudden power cut ensures that important test results are not lost. Our Visible Spectrophotometer have grating optical system that ensures high spectral resolution.

Visible Spectrophotometer FM-VS-A100

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Visible Spectrophotometer FM-VS-A101

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog
Visible Spectrophotometer FM-VS-A102
  • Wavelength range : 320 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer

Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

Single Beam UV-Visible Spectrophotometer FM-UVS-A101
  • Wavelength range : 200 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A102

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A103

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Fluorescence Spectrophotometer

Fison Fluorescence Spectrophotometers offer high sensitivity and selectivity, detecting low-concentration samples with superior accuracy. They are equipped with an advanced optical system, ensuring precise detection. These units provide automatic wavelength adjustment for accurate and consistent wavelength selection. They feature a user-friendly interface, offering a digital display and control system for easy operation. Our spectrophotometers come with a compact and durable construction for long-term reliability.

Fluorescence Spectrophotometer FM-FS-A100
  • Light source : LED
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10nm
Catalog
Fluorescence Spectrophotometer FM-FS-A101
  • Light source : Xenon lamp 150 W
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10 nm
Catalog

Fluorescence Spectrophotometer FM-FS-A200

  • Light source : 150 W xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
Catalog

Double Beam UV-Visible Spectrophotometer

Fison Double Beam UV-Visible Spectrophotometers provide high-precision optical system. They provide accurate and stable measurement of absorbance and transmittance. These units feature a double beam design, simultaneously measuring the sample and reference to reduce errors and improve accuracy. They include USB and printer connectivity, enabling seamless data transfer and efficient reporting. Our spectrophotometers offer a wide wavelength range for versatile analytical applications.

Double Beam UV-Visible Spectrophotometer FM-UVS-C100

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C101
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.0 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C102
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 0.5, 1, 2 and 4 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer

Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B100

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B101

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B102
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog