Atomic Absorption Spectrophotometer FM-AAS-A100 is a fast and accurate microprocessor controlled analyzer with built-in computer data processing and LCD display. Analysis of metal ions by air-acetylene flame and graphite furnace atomizer with absorption at 190 to 900 nm wavelength. Features Czerny-Turner monochromator 1200 line/mm grating optics, paired with D2 background correction avails greater performance. Multiple atomizer configurations allow high-intensity analysis and ultimate ease of use within multiple applications settings such as environmental, agricultural and clinical, as well as high throughput labs.
Specifications
Wavelength range | 190 to 900 nm |
Wavelength accuracy | ≤ ±0.5 nm |
Wavelength repeatability | ≤0.3 nm (single direction) |
Spectrum bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
Resolution | < 40% |
Base line stability | ±0.004 Abs/30 min |
Grating | 1200 lines / mm |
Inflamer | All-metal titanium burner with 10 cm slit |
Atomizer | Efficient glass atomizer |
Lamp | Hollow cathode lamp |
Lamp stand | 6 lamps automatic turret, automatic alignment |
Characteristic concentration of copper | ≤0.04 mg/ml/1% |
Detection limit of copper | ≤0.008 mg/ml |
D2 Background calibration ability | Greater than 30 times |
Flame system | Air-acetylene flame system |
Protection system | Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner |
Standard interface | RS232 |
Power supply | 220 V/ 50 Hz, 3 A |
Gross weight | 160 kg |
Features
Applications
Accessories
Accessories no | Accessories name |
1. | Oil-free air compressor |
2. | Glass Atomizer |
3. | Cu Hollow cathode lamp |
4. | Atomizer unit |
5. | Burner unit |
6. | Dust cover |
7. | Water-separating gas filter |
8. | Titanium burner: slit 10 cm |
Accessories Optional
Accessories no | Accessories name |
1 | GRAPHITE FURNACE SYSTEM: |
Heating steps- 9 steps | |
Temperature range: 20°C to 3000°C | |
Slope heating time: 0 to 999 s | |
Heating holding time: 0 to 999 s | |
Inert gas: argon | |
Inert gas pressure: 0.3 MPa | |
Cooling water flow rate: 2 L/min | |
Characteristic quantity: (Cd) ≤ 1 × 10 -12 g, (Cu) ≤ 1 × 10 -10 g | |
Power supply: 220 V/50 Hz 3A | |
Ambient temperature: 10 to 30 °C | |
Relative humidity: less than 85% | |
2 | Hydride generator |
3 | Graphite tubes |
4 | Acetylene Regulator |
5 | Printer |
6 | Software |
Fison Atomic Absorption Spectrophotometers offer high precision and sensitivity for detecting metal concentrations in various samples. They feature an advanced optical system with a high-resolution monochromator for enhanced spectral accuracy. These units provide automated sample handling, reducing manual intervention. They include a user-friendly interface and digital controls for easy operation. Our spectrophotometers deliver multiple calibration modes, allowing single and multi-element analysis to ensure versatility.
Wavelength range | 190 to 900 nm |
Wavelength accuracy | ±0.5 nm |
Resolution | Two spectral lines of Mn at 279.5 nm and 279.8 nm, can be separated with spectral bandwidth of 0.2 nm and valley-peak energy ratio less than 30% |
Baseline stability | 0.005 A/30 min |
Background correction | D2 lamp background correction capability at 1A is better than 30 times |
Lamp turret | 2 lamps powered simultaneously (one preheated) |
Lamp current adjustment | 0 to 20 mA |
Lamp power supply mode | 400 Hz square wave pulse |
Monochromator | Single beam, Czerny-Turner design grating monochromator |
Grating | 1800 lines/mm |
Focal length | 277 mm |
Blazed wavelength | 250 nm |
Spectral bandwidth | 0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm, automatic change |
Spectral adjustment | Manual adjustment for wavelength and slit |
Wavelength range | 190 to 900 nm |
Wavelength accuracy | ± 0.25 nm |
Resolution | Two spectral lines of Mn at 279.5 nm and 279.8 nm can be separated with the spectral bandwidth of 0.2 nm and valley peak energy ratio less than 30% |
Baseline stability | ≤0.004 A/30 min |
Background correction | D2 lamp background correction capability at 1A is better than 30 times |
Lamp turret | 4-lamp turret auto alignment, fully automated scan and peak-picking |
Lamp current adjustment | Automatic adjustment and display Wide pulse current: 0 to 25 mA, Narrow pulse current: 0 to 10 mA |
Lamp power supply mode | 400 Hz square wave pulse |
Monochromator | Single beam, Czerny-Turner design grating monochromator |
Grating | 1800 lines/mm |
Focal length | 277 mm |
Blazed wavelength | 250 nm |
Spectral bandwidth | 0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm automatic change |
Fison Visible Spectrophotometer features a high-resolution LCD screen, offering clear and precise monitoring of parameters. They automatically set the wavelength, ensuring precise adjustments and simplifying the measurement process for accurate results. The large sample compartment fits cuvettes with various path lengths for efficient testing. Their data restoration after a sudden power cut ensures that important test results are not lost. Our Visible Spectrophotometer have grating optical system that ensures high spectral resolution.
Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.
Fison Fluorescence Spectrophotometers offer high sensitivity and selectivity, detecting low-concentration samples with superior accuracy. They are equipped with an advanced optical system, ensuring precise detection. These units provide automatic wavelength adjustment for accurate and consistent wavelength selection. They feature a user-friendly interface, offering a digital display and control system for easy operation. Our spectrophotometers come with a compact and durable construction for long-term reliability.
Fison Double Beam UV-Visible Spectrophotometers provide high-precision optical system. They provide accurate and stable measurement of absorbance and transmittance. These units feature a double beam design, simultaneously measuring the sample and reference to reduce errors and improve accuracy. They include USB and printer connectivity, enabling seamless data transfer and efficient reporting. Our spectrophotometers offer a wide wavelength range for versatile analytical applications.
Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.