Our specialists will reach out shortly.

Atomic Absorption Spectrophotometer FM-AAS-A100

Atomic Absorption Spectrophotometer FM-AAS-A100

Atomic Absorption Spectrophotometer FM-AAS-A100 is a fast and accurate microprocessor controlled analyzer with built-in computer data processing and LCD display. Analysis of metal ions by air-acetylene flame and graphite furnace atomizer with absorption at 190 to 900 nm wavelength. Features Czerny-Turner monochromator 1200 line/mm grating optics, paired with D2 background correction avails greater performance. Multiple atomizer configurations allow high-intensity analysis and ultimate ease of use within multiple applications settings such as environmental, agricultural and clinical, as well as high throughput labs.

Specifications

Wavelength range  190 to 900 nm
Wavelength accuracy ≤ ±0.5 nm
Wavelength repeatability ≤0.3 nm (single direction)
Spectrum bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Resolution < 40%
Base line stability ±0.004 Abs/30 min
Grating 1200 lines / mm
Inflamer All-metal titanium burner with 10 cm slit
Atomizer Efficient glass atomizer
Lamp Hollow cathode lamp
Lamp stand 6 lamps automatic turret, automatic alignment
Characteristic concentration of copper ≤0.04 mg/ml/1%
Detection limit of copper ≤0.008 mg/ml
D2 Background calibration ability Greater than 30 times
Flame system Air-acetylene flame system
Protection system Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner
Standard interface RS232
Power supply 220 V/ 50 Hz, 3 A
Gross weight 160 kg

Features

  • Integrated flame/graphite furnace atomization system, changeable with flame emission burner
  • Turret for 6 pre-aligned hollow cathode lamps fitted with pre-heating, and individual pre-centered lamps
  • Spectral bandwidth of 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Characteristic concentration of copper: ≤ 0.04 mg/ml/1%
  • Detection limit of copper: ≤0.008 mg/ml
  • Built-in computer data processing system and LCD display
  • Double-beam system compensates light source and wavelength drift caused by temperature variation
  • Gas path system equipped with precision pressure stabilizing and current stabilizing devices
  • Multi-functional analysis mode: flame absorption, flame emission, graphite furnace atomic absorption and hydride generation
  • Integrated functions: integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting
  • Various parameters and working curves displayed in screen and report printing
  • It is equipped with autosampler and RS232 interface for externally linking PC

Applications

  • Used in different areas of chemistry such as clinical analysis of metals in biological fluids and tissues such as whole blood, plasma, urine, saliva, brain tissue, liver, hair, muscle tissue, semen, in some pharmaceutical manufacturing processes, minute quantities of a catalyst that remain in the final drug product, and analyzing water for its metal content.

Accessories

  • Accessories no Accessories name
    1.        Oil-free air compressor
    2.        Glass Atomizer
    3.        Cu Hollow cathode lamp
    4.        Atomizer unit
    5.        Burner unit
    6.        Dust cover
    7.        Water-separating gas filter
    8.        Titanium burner: slit 10 cm

Accessories Optional

  • Accessories no Accessories name
    1 GRAPHITE FURNACE SYSTEM:
    Heating steps- 9 steps
    Temperature range: 20°C to 3000°C
    Slope heating time: 0 to 999 s
    Heating holding time: 0 to 999 s
    Inert gas: argon
    Inert gas pressure: 0.3 MPa
    Cooling water flow rate: 2 L/min
    Characteristic quantity: (Cd) ≤ 1 × 10 -12 g, (Cu) ≤ 1 × 10 -10 g
    Power supply: 220 V/50 Hz 3A
    Ambient temperature: 10 to 30 °C
    Relative humidity: less than 85%
    2 Hydride generator
    3 Graphite tubes
    4 Acetylene Regulator
    5 Printer
    6 Software

Alternative Models Of Atomic Absorption Spectrophotometer

Fison Atomic Absorption Spectrophotometers offer high precision and sensitivity for detecting metal concentrations in various samples. They feature an advanced optical system with a high-resolution monochromator for enhanced spectral accuracy. These units provide automated sample handling, reducing manual intervention. They include a user-friendly interface and digital controls for easy operation. Our spectrophotometers deliver multiple calibration modes, allowing single and multi-element analysis to ensure versatility.

Atomic Absorption Spectrophotometer FM-AAS-A101

  • Wavelength range : 190 to 900 nm
  • Wavelength accuracy: ± 0.15 nm
  • Wavelength repeatability: ≤ 0.04 nm
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A200

  • Main specification:
    Wavelength range190 to 900 nm
    Wavelength accuracy±0.5 nm
    ResolutionTwo spectral lines of Mn at 279.5 nm and 279.8 nm, can be separated with spectral bandwidth of 0.2 nm and valley-peak energy ratio less than 30%
    Baseline stability0.005 A/30 min
    Background correctionD2 lamp background correction capability at 1A is better than 30 times
  • Light source system:
    Lamp turret2 lamps powered simultaneously (one preheated)
    Lamp current adjustment0 to 20 mA
    Lamp power supply mode400 Hz square wave pulse
  • Optical system:
    MonochromatorSingle beam, Czerny-Turner design grating monochromator
    Grating1800 lines/mm
    Focal length277 mm
    Blazed wavelength250 nm
    Spectral bandwidth0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm, automatic change
    Spectral adjustmentManual adjustment for wavelength and slit
Catalog

Atomic Absorption Spectrophotometer FM-AAS-A201

  • Main specification:
    Wavelength range190 to 900 nm
    Wavelength accuracy± 0.25 nm
    ResolutionTwo spectral lines of Mn at 279.5 nm and 279.8 nm can be separated with the spectral bandwidth of 0.2 nm and valley peak energy ratio less than 30%
    Baseline stability≤0.004 A/30 min
    Background correctionD2 lamp background correction capability at 1A is better than 30 times
  • Light source system:
    Lamp turret4-lamp turret auto alignment, fully automated scan and peak-picking
    Lamp current adjustmentAutomatic adjustment and display
    Wide pulse current: 0 to 25 mA,
    Narrow pulse current: 0 to 10 mA                
    Lamp power supply mode400 Hz square wave pulse
  • Optical system:
    MonochromatorSingle beam, Czerny-Turner design grating monochromator
    Grating1800 lines/mm
    Focal length277 mm
    Blazed wavelength250 nm
    Spectral bandwidth0.1 nm, 0.2 nm, 0.4 nm, 1.2 nm automatic change
Catalog

Visible Spectrophotometer

Fison Visible Spectrophotometer features a high-resolution LCD screen, offering clear and precise monitoring of parameters. They automatically set the wavelength, ensuring precise adjustments and simplifying the measurement process for accurate results. The large sample compartment fits cuvettes with various path lengths for efficient testing. Their data restoration after a sudden power cut ensures that important test results are not lost. Our Visible Spectrophotometer have grating optical system that ensures high spectral resolution.

Visible Spectrophotometer FM-VS-A100

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Visible Spectrophotometer FM-VS-A101

  • Wavelength range : 325 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog
Visible Spectrophotometer FM-VS-A102
  • Wavelength range : 320 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer

Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

Single Beam UV-Visible Spectrophotometer FM-UVS-A101
  • Wavelength range : 200 nm to 1000 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A102

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam UV-Visible Spectrophotometer FM-UVS-A103

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Fluorescence Spectrophotometer

Fison Fluorescence Spectrophotometers offer high sensitivity and selectivity, detecting low-concentration samples with superior accuracy. They are equipped with an advanced optical system, ensuring precise detection. These units provide automatic wavelength adjustment for accurate and consistent wavelength selection. They feature a user-friendly interface, offering a digital display and control system for easy operation. Our spectrophotometers come with a compact and durable construction for long-term reliability.

Fluorescence Spectrophotometer FM-FS-A100
  • Light source : LED
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10nm
Catalog
Fluorescence Spectrophotometer FM-FS-A101
  • Light source : Xenon lamp 150 W
  • Exciting optical system : Interference optical filter
  • Optical filter bandwidth : 10 nm
Catalog

Fluorescence Spectrophotometer FM-FS-A200

  • Light source : 150 W xenon lamp
  • Excitation wavelength : 200 nm to 900 nm
  • Emission wavelength : 200 nm to 900 nm
Catalog

Double Beam UV-Visible Spectrophotometer

Fison Double Beam UV-Visible Spectrophotometers provide high-precision optical system. They provide accurate and stable measurement of absorbance and transmittance. These units feature a double beam design, simultaneously measuring the sample and reference to reduce errors and improve accuracy. They include USB and printer connectivity, enabling seamless data transfer and efficient reporting. Our spectrophotometers offer a wide wavelength range for versatile analytical applications.

Double Beam UV-Visible Spectrophotometer FM-UVS-C100

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C101
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.0 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog
Double Beam UV-Visible Spectrophotometer FM-UVS-C102
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 0.5, 1, 2 and 4 nm
  • Optical system : Double beam, grating 1200 lines / mm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer

Fison Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B100

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 4 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog

Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B101

  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 2 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog
Single Beam Scanning UV-Visible Spectrophotometer FM-UVS-B102
  • Wavelength range : 190 nm to 1100 nm
  • Spectral bandwidth : 1.8 nm
  • Optical system : Single beam, grating 1200 lines / mm
Catalog